> For the complete documentation index, see [llms.txt](https://wiki.openelab.io/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://wiki.openelab.io/robotics/myactuator/rmd-x4-p12-10-e-development-guide.md). Agents can also search and read this documentation through its [MCP server](https://wiki.openelab.io/~gitbook/mcp).

# MyActuator RMD-X4-P12-10-E Development Guide

Exact-model specifications, wiring, first CAN status read, troubleshooting and official technical resources.

{% hint style="info" %}
[**View MyActuator RMD-X4-P12-10-E on OpenELAB**](https://openelab.io/products/myactuator-rmd-x4-p12-actuator)

**Model:** RMD-X4-P12-10-E · **SKU:** `MyActuator-RMD-X4-P12-10-E` · **Revision / option:** X4-10 E model; parameter sheet 260920
{% endhint %}

## Product overview

The X4-10 is the higher-speed, lower-ratio X4 option. The OpenELAB order code uses P12, while the manufacturer parameter sheet specifies 12.5:1 and the mechanical drawing uses P12.5. These naming forms must not be confused with the 36:1 X4 models.

![MyActuator RMD-X4-P12-10-E, product photograph from OpenELAB](https://1292444914-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FtgOfPnscWebs1eh82EKq%2Fuploads%2FXNKhLt6Brwkh5Zjaip0J%2Fmyactuator-x4.jpg?alt=media)

Product photograph: OpenELAB product listing. Check the ordered option for package contents; accessories shown in manufacturer packaging examples are not a guarantee that the selected motor-only variant includes them.

## Applications

Consider it for compact rotary axes where speed is more important than the higher output torque of the X4-P36. Check the 4 N·m rated torque and output-bearing loads before attaching a mechanism.

## Specifications

| Parameter                    | Value / scope                      |
| ---------------------------- | ---------------------------------- |
| Actual reduction ratio       | 12.5:1                             |
| Nominal supply / range       | 24 V DC / 20–55 V                  |
| Rated / peak output torque   | 4 / 10 N·m                         |
| Rated / no-load output speed | 238 / 317 rpm                      |
| Rated output power           | 100 W                              |
| Rated / peak phase current   | 7.8 / 19.5 Arms                    |
| Input / output encoder       | 17-bit / 18-bit absolute           |
| Backlash                     | ≤15 arcmin                         |
| Bearing / mass               | Deep-groove ball bearing / 0.33 kg |
| Interface / brake            | CAN and EtherCAT / no brake        |

Source: [RMD-X4-P12-10-E parameter sheet / drawings (X4-10 E model; parameter sheet 260920)](https://www.myactuator.com/_files/archives/cab28a_50c5251d50b24345bc0c05c2cfcda7b6.zip). Rated and peak figures are distinct operating points, not simultaneous maxima.

Use 12.5:1 where the host explicitly needs a motor-to-output ratio. The 260920 sheet is the basis for the values here; do not copy motor constants or commutation parameters from another X4 listing.

## Hardware and connections

Required equipment: a secured unloaded actuator, a 24 V DC nominal (20–55 V operating range) supply, suitable power wiring and isolation, one CAN interface with its supported host software, and the model-specific mating cables. Phase current in a motor table is not a substitute for calculating the DC supply requirement.

Use the exact [model drawing / parameter archive](https://www.myactuator.com/_files/archives/cab28a_50c5251d50b24345bc0c05c2cfcda7b6.zip) and [generation manual](https://www.myactuator.com/_files/archives/cab28a_a5b8b24b40ac4f6d87bae373b0de459a.zip) for connector orientation and screw depth. Connect the external supply to VCC/DC+ and GND/DC−; connect CAN\_H to CAN\_H and CAN\_L to CAN\_L with the documented common reference. Do not infer a pin number from a product photograph or use communication pins as power inputs.

For EtherCAT, distinguish the actuator's IN and OUT ports and preserve the T+/T− and R+/R− differential pairs. Use the matching cable/adapter and ESI. The RJ45 adapter is a connector interface, not a substitute for an EtherCAT master.

For a CAN bench connection, use a linear bus with 120 Ω termination at each physical end and a common reference as specified by the manufacturer. Count any built-in USB-CAN termination; do not add a resistor at every motor. With power off, two 120 Ω end resistors in parallel measure about 60 Ω between CAN\_H and CAN\_L. This resistance check is a wiring diagnostic, not proof of communication.

## Software and development resources

The [manufacturer setup-software page](https://www.myactuator.com/downloads-setupsoftware) is the source for the setup utility and its supported model list. The [X manual bundle](https://www.myactuator.com/_files/archives/cab28a_a5b8b24b40ac4f6d87bae373b0de459a.zip) includes CAN protocol V4.4-260425 and EtherCAT protocol V2.0-260425. The public setup-software list does not explicitly name X4-10; use the documented raw CAN status check below and obtain an exact-model preset before using model-specific GUI tuning.

A compatible raw CAN frame utility is sufficient for the first result below. Install the driver that matches the actual USB-CAN hardware and host operating system; this guide does not assume that the adapter exposes Linux SocketCAN or a serial COM protocol. The manufacturer's [SDK downloads](https://www.myactuator.com/downloads-sdk) provide optional integration starting points. Their exact OS, dependency and model coverage must be checked in the selected release before building; no SDK build is required for this status-read procedure. Preserve calibration and parameter backups before any firmware change.

For EtherCAT integration, use the [official ESI downloads](https://www.myactuator.com/downloads-ethercatesi) and the protocol's object dictionary for the fitted firmware. Confirm slave identity and process-data mapping before enabling operation.

## Getting started

### First working result: read status over CAN

1. Record the label, controller/firmware revision and saved motor ID. Connect only one unloaded motor; secure it and leave motion disabled.
2. With power off, connect power and CAN as described above. Verify polarity, common reference and the two end terminations. Set the supply within the documented range; use nominal voltage for rated-condition work.
3. Install the interface's matching driver, open the CAN utility and select its channel. For the cited protocol, select **1 Mbit/s, standard 11-bit data frames, DLC 8**. If this motor has a previously changed bitrate, use that saved setting rather than writing a new one blindly.
4. Send one read-status command to arbitration ID **0x140 + motor ID**. For a motor confirmed as ID 1, enter transmit ID **0x141** and payload **9A 00 00 00 00 00 00 00**. ID 1 is an example, not a discovery result.
5. Inspect the reply at **0x240 + motor ID** (**0x241** for ID 1). The command byte should be 0x9A. Decode temperature, bus voltage and fault flags using the **Read Motor Status 1 and Error Flag** table in the [cited protocol package](https://www.myactuator.com/_files/archives/cab28a_a5b8b24b40ac4f6d87bae373b0de459a.zip); byte layouts can differ across firmware generations.
6. Repeat the read and record the actual voltage, temperature and fault state. Resolve any fault before a separate motion test. Only after confirming angle units, direction, current limits and stop behavior should a bounded, low-speed, unloaded movement be attempted.

**Expected result:** repeatable status replies from the intended ID, with plausible bus voltage/temperature and fault information that can be decoded for the recorded firmware. A status reply establishes communication, not motion or load qualification.

**If this check fails:** verify supply at the actuator, adapter enumeration, CAN\_H/CAN\_L and reference wiring, termination, saved bitrate and ID, then protocol/firmware pairing. Do not repeatedly send enable or motion commands to diagnose a missing reply.

## Troubleshooting and FAQs

**P12 or P12.5?**

The store SKU is RMD-X4-P12-10-E; the actual reduction in the manufacturer's sheet is 12.5:1. Retain the full store SKU when ordering.

**Can the X4-P36 tuning be reused?**

No. Ratio, speed and output torque differ. Retain the factory settings for the exact actuator, and confirm command units before tuning.

**Supply current does not match 7.8 A**

The table specifies phase RMS current. DC-bus current depends on speed, load and drive efficiency and is not equal to that figure in every condition.

**EtherCAT cable is connected but the slave is absent**

Check motor power, IN/OUT direction, cable pair mapping and the master's active interface. Then verify ESI/product identity and inspect master diagnostics before changing drive parameters.

## Downloads and technical documents

| Resource                                       | Purpose and revision                                                                                                                             | Link                                                                                                   |
| ---------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------ | ------------------------------------------------------------------------------------------------------ |
| Exact-model parameters and mechanical drawings | RMD-X4-P12-10-E parameter sheet / drawings (X4-10 E model; parameter sheet 260920); use supplied drawings/CAD rather than dimensions from images | [Official ZIP](https://www.myactuator.com/_files/archives/cab28a_50c5251d50b24345bc0c05c2cfcda7b6.zip) |
| Manuals and protocols                          | X V4 manual 261029, user manual V1.1, CAN V4.4-260425, EtherCAT V2.0-260425                                                                      | [Official ZIP](https://www.myactuator.com/_files/archives/cab28a_a5b8b24b40ac4f6d87bae373b0de459a.zip) |
| Model document center                          | Current revision listings and CAD packages                                                                                                       | [Manufacturer downloads](https://www.myactuator.com/downloads-xseries)                                 |
| Host setup utility                             | Select model/driver generation before installation                                                                                               | [Setup software](https://www.myactuator.com/downloads-setupsoftware)                                   |
| Optional development SDK                       | Check release README, dependencies and licensing before use                                                                                      | [SDK downloads](https://www.myactuator.com/downloads-sdk)                                              |
| EtherCAT ESI                                   | Match actuator firmware/product identity                                                                                                         | [ESI downloads](https://www.myactuator.com/downloads-ethercatesi)                                      |

## References and validation

The specifications and procedure use the manufacturer packages linked above; the [OpenELAB listing](https://openelab.io/products/myactuator-rmd-x4-p12-actuator) identifies the sold model and options. Reviewed 19 November 2026. Manufacturer PDFs, relevant tables and interface documentation were inspected. The CAN procedure is a documentation-based first check; software compilation, adapter-driver installation and physical motor tests were **not run**. Keep the actual firmware, host environment, ID and measured results with the device.

[All MyActuator product guides](https://wiki.openelab.io/robotics/myactuator.md)